Dry Type Isolation Transformer China

Model: Custom Three-Phase Series

Capacity
100 kVA–12 MVA
Primary voltage
Up to 35 kV
Insulation
Cast resin, Class F/H
Cooling
AN or AF
  • Rated capacity100 kVA–12 MVA
  • Primary voltageUp to 35 kV
  • InsulationCast resin, Class F or H
  • CoolingAN or AF
  • MOQ1 unit
  • SupplyMade to order

The 100 kVA–12 MVA range provides configurable voltage ratio, vector group, impedance, cooling and enclosure for industrial, data-center and commercial loads. Galvanic isolation, cast-resin insulation and routine IEC testing protect sensitive equipment while supporting oil-free indoor installation. cnbbelc customizes windings, taps, monitoring and shipping documentation for export projects.

Load, Voltage and Site Data Determine Rated Capacity

This product range serves engineered three-phase projects from 100 kVA to 12 MVA rather than small plug-in isolation transformer applications. Start with continuous kVA, motor-starting or inrush duty, harmonic-producing loads, primary and secondary voltage, 50/60 Hz frequency, phase arrangement, vector group and grounding method. These inputs determine conductor size, core flux, impedance and the thermal margin required at rated load.

Site information covers indoor or outdoor location, ambient temperature, altitude, available ventilation, enclosure protection, cable-entry direction, lifting route and space limits. AN cooling suits installations with sufficient natural airflow; AF adds fans when the approved design requires more heat removal or controlled overload capability.

The quotation package converts those inputs into a rated capacity, voltage ratio, winding material, impedance, insulation class, temperature rise, enclosure, losses and overall dimensions. cnbbelc can also provide an outline drawing, terminal arrangement and proposed routine test schedule so the electrical and mechanical interfaces can be approved before manufacturing begins.

Galvanic Isolation Protects the Load; Cooling Protects the Transformer

Three functions should be specified separately. Galvanic isolation comes from physically separate primary and secondary windings. An optional grounded electrostatic shield can reduce capacitive coupling of common-mode electrical noise. The insulation, cooling and temperature-control system then keep the transformer itself inside its approved thermal limits.

FeaturePrimary purposeApplicable situationQuotation detail
Galvanic isolationSeparates the source circuit from the load circuit while transferring AC power magnetically.Sensitive equipment, new grounding arrangements or safety-driven separation require independent windings.Voltage ratio, vector group, grounding and dielectric test level.
Electrostatic shieldProvides a grounded barrier between windings to reduce capacitive noise transfer.Automation, UPS, data-center or instrumentation loads have a defined common-mode noise requirement.Shield location, grounding terminal and any required attenuation test.
Thermal monitoring and coolingDetects winding temperature and removes heat through AN or AF airflow.Room temperature, altitude, enclosure or load profile reduces natural cooling margin.Class F/H insulation, PT100 sensors, fan-start, alarm and trip set points.

A dry type transformer avoids insulating oil, but it still needs clear airflow and a clean installation environment. The project specification includes dust, humidity, salt mist, corrosive atmosphere, seismic duty and altitude before design. Isolation does not correct every voltage dip or harmonic problem; those performance requirements need their own winding, impedance, shielding or filtering provisions.

cnbbelc Engineers, Tests and Packs Each Transformer for the Project

cnbbelc configures rated capacity, primary and secondary voltage, vector group, impedance, copper or aluminum windings, taps, insulation class, AN/AF cooling, enclosure protection, temperature sensors, cable entry and installation dimensions around the approved system data. The same engineering process supports industrial drives, data centers, renewable-energy equipment, marine and shore-power projects.

Finished-unit verification can include visual inspection, winding resistance, voltage ratio and vector group, insulation resistance, impedance and load loss, no-load current and loss, applied-voltage and induced-voltage tests, plus partial-discharge measurement when required by the design. Each ordered configuration is released against its approved drawing and routine test report; witnessed or third-party tests can be added to the contract scope.

The base order quantity is one transformer. A preliminary proposal normally takes 3–5 working days, and the base production window is 30–45 working days after drawing approval and deposit. The unit is protected against moisture, secured to an export base or plywood package, and shipped with the approved drawing, nameplate data, routine test record and packing list.

Electrical and Construction Specifications

Final ratings, losses, impedance, temperature rise and dimensions are stated on the approved project drawing and technical schedule.

ProductDry Type Isolation Transformer China
SeriesCustom Three-Phase Series
Rated capacity100 kVA–12 MVA
VoltagePrimary up to 35 kV; secondary voltage engineered to the load
Frequency and phase50/60 Hz, three phase
Core and windingsCRGO silicon-steel core; copper or aluminum conductors
Insulation and coolingCast resin, Class F or H; AN or AF
ConnectionsProject-specific vector group, taps, terminals and cable entry
Standards and traceabilityIEC 60076-11 / GB/T 1094.11 basis; nameplate, serial number, approved drawing and routine test report
Packing unit1 transformer per moisture-protected export package

Rated Operating Conditions and Protection Inputs

The approved design links electrical ratings to ambient temperature, altitude, ventilation, enclosure and the actual load profile.

100 kVA–12 MVARated capacity
Up to 35 kVPrimary voltage
50/60 HzFrequency
Class F/HInsulation system
Insulating and cooling mediumOil-free cast resin with indoor air cooling
Ambient temperatureBase design: -5°C to 40°C (23°F to 104°F); specify other conditions
Electrical loadContinuous rated kVA after motor starting, inrush and harmonic content are included in sizing
Installation limitsState altitude, ventilation, enclosure, clearances, cable entry, grounding and contaminant exposure before approval

Ordering, Price Basis and Delivery

The starting price applies to a base 100 kVA indoor configuration. Capacity, voltage, enclosure, tests, destination and copper market conditions determine the final quotation.

  • MOQ1 unit
  • Pre-production approvalEngineering proposal and approved drawing; no separate production sample
  • Proposal lead time3–5 working days
  • Production lead time30–45 working days after drawing approval and deposit for the base configuration
  • Starting price and availabilityFrom USD 6,800 per unit; PreOrder (made to order)
  • PackagingMoisture barrier, secured base and export plywood protection with lifting marks
  • Payment30% T/T deposit; 70% before shipment after routine test records are available
  • ShippingFOB Shanghai by sea or buyer-arranged pickup; final dimensions and gross weight follow the approved drawing

Transformer Engineering and Manufacturing by Shanghai Beibian

The manufacturer supports application-specific transformer design from technical review through finished-product testing and export packing.

Shanghai Beibian transformer manufacturing facility

Shanghai Beibian Technology Co., Ltd.

Shanghai Beibian Technology Co., Ltd. designs and manufactures special transformers and power-conversion equipment. Its manufacturing locations include Shanghai Songjiang, Wenzhou and Jinan, with project work covering industrial drives, data centers, renewable energy, marine and shore-power systems.

  • Project design for capacity, voltage, impedance, insulation, cooling and enclosure
  • CRGO core construction with cast-resin or VPI processes selected by product design
  • Finished-product electrical testing and OQC inspection before packing
  • Approved drawings, test records and export documentation supplied with the order

Standards and Compliance Documents Available for Review

The purchase specification identifies the required market, product configuration and certificate scope. Copies are supplied for review when they apply to the ordered unit.

  • ISO management system documentationAvailable on request
  • CE, ETL and UL market or safety documentationAvailable on request for the verified product scope
  • RoHS and REACH material-compliance documentationAvailable on request
  • IEC 60076-11 / GB/T 1094.11 routine test reportSupplied for the ordered configuration

Send the Load, Voltage, Site and Quantity for a Quote

Include the load type, continuous kVA, primary and secondary voltage, frequency, vector group, enclosure, ambient conditions and destination.